{"id":114853,"date":"2026-08-21T17:07:16","date_gmt":"2026-08-21T15:07:16","guid":{"rendered":"https:\/\/preprod.marechal.com\/breaking-capacity-expert-sheet\/"},"modified":"2026-09-10T14:56:24","modified_gmt":"2026-09-10T12:56:24","slug":"breaking-capacity-expert-sheet","status":"publish","type":"page","link":"https:\/\/marechal.com\/en\/breaking-capacity-expert-sheet\/","title":{"rendered":"Breaking capacity expert sheet"},"content":{"rendered":"<header\n    class=\"hero-page hero-page--centered\"\n    >\n            <img class=\"hero-page__bg\" src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-scaled.webp\" srcset=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-scaled.webp 2560w, https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-300x101.webp 300w, https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-1024x344.webp 1024w, https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-768x258.webp 768w, https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-1536x516.webp 1536w, https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/marechal-header-expert-sheets-background-2048x688.webp 2048w\" sizes=\"100vw\" alt=\"\" aria-hidden=\"true\" fetchpriority=\"high\" loading=\"eager\" decoding=\"async\" \/>\n        \n    <div class=\"hero-page__content\">\n        <div class=\"hero-page__container\">\n                                                <h1 class=\"hero-page__title\">Breaking capacity<br \/>expert sheet<\/h1>                                                                    <\/div>\n    <\/div>\n\n        <\/header>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\">Breaking capacity<\/h2>\n\n\n<section class=\"expertise-section expertise-section--text expertise-section--dark expertise-section--text-center\">\n\n    \n        <div class=\"container\">\n                        \n            \n                                    <div class=\"expertise-section__text\">\n                        <p><strong>To guarantee the safety of users and installations, a plug  socket-outlet must be able to:<\/strong><\/p>\n                    <\/div>\n                                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"text-columns text-columns--numbered\">\n    <div class=\"container\">\n        <div class=\"text-columns__inner\">\n                            <div class=\"text-columns__col\">\n                                            <div class=\"text-columns__text\"><p>Prevent accidental or unintentional removal of a plug from its socket<\/p>\n<\/div>\n                                                        <\/div>\n                            <div class=\"text-columns__col\">\n                                            <div class=\"text-columns__text\"><p>Resist accidental closure on fault current (blocked engine, damaged cable&#8230;)<\/p>\n<\/div>\n                                                        <\/div>\n                            <div class=\"text-columns__col\">\n                                            <div class=\"text-columns__text\"><p>Be connected and disconnected under normal load and in overload conditions (or in an emergency) or in the case of a machine with residual inductive current<\/p>\n<\/div>\n                                                        <\/div>\n                            <div class=\"text-columns__col\">\n                                            <div class=\"text-columns__text\"><p>Be short-circuit proof<\/p>\n<\/div>\n                                                        <\/div>\n                    <\/div>\n    <\/div>\n<\/section>\n\n\n\n<h6 class=\"wp-block-heading has-text-align-center\">Standard IEC\/EN 60309-1 &#8211; Plug  socket-outlets for industrial use<\/h6>\n\n\n<section class=\"expertise-section expertise-section--text expertise-section--dark expertise-section--text-center\">\n\n    \n        <div class=\"container\">\n                        \n            \n                                    <div class=\"expertise-section__text\">\n                        <p>According to IEC\/EN 60309-1, appliances without interlock must have sufficient breaking capacity. Compliance is checked by testing each appliance with a new complementary appliance.<br \/>\nCompliance with this standard is assessed by the same appliance passing the successive tests of sections 20 (breaking capacity), 21 (normal operation) and 22 (temperature rise). Any failure invalidates the entire set.<\/p>\n                    <\/div>\n                                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"text-columns text-columns--tables\">\n    <div class=\"container\">\n        <div class=\"text-columns__inner\">\n                            <div class=\"text-columns__col\">\n                                                                <img decoding=\"async\" class=\"text-columns__image\" src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4335.webp\"\n                             alt=\"\" loading=\"lazy\" \/>\n                                    <\/div>\n                            <div class=\"text-columns__col\">\n                                                                <img decoding=\"async\" class=\"text-columns__image\" src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4336.webp\"\n                             alt=\"\" loading=\"lazy\" \/>\n                                    <\/div>\n                    <\/div>\n    <\/div>\n<\/section>\n\n\n<section class=\"expertise-section expertise-section--text expertise-section--dark expertise-section--text-center\">\n\n    \n        <div class=\"container\">\n                        \n            \n                                    <div class=\"expertise-section__text\">\n                        <h3>Standard IEC 60309-4 &#8211; Plug socket-outlets and couplers for industrial purposes &#8211; Part 4: Switch-controlled plugs, socket-outlets and couplers with or without interlock.<\/h3>\n<p style=\"text-align: left\">This standard applies to plug socket-outlets with a switching element, including those with a built-in circuit-breaking device. Section 20 of IEC\/EN 60309-1 is applicable for compliance, with the following exception:<\/p>\n<ul style=\"text-align: left\">\n<li>An electrical base or a mobile socket-outlet partnered with a switch without a locking device shall be tested with the switching device in the closed position.<\/li>\n<li>A base or a mobile plug socket-outlet with an onboard switching device without an interlocking device must be tested twice:\n<ul>\n<li>the first test with the switching device in the closed position (test of the base or mobile plug socket-outlet)<\/li>\n<li>a second time with the plug which operates the switching device still inserted in the base or mobile plug socket-outlet (switch test)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p style=\"text-align: center\"><strong>DECONTACTOR<sup>\u2122<\/sup> are covered by this standard.<\/strong><\/p>\n                    <\/div>\n                                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"expertise-section expertise-section--text expertise-section--dark expertise-section--text-center\">\n\n    \n        <div class=\"container\">\n                        \n            \n                                    <div class=\"expertise-section__text\">\n                        <h2>Standard IEC 60947-3 &#8211; Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units.<\/h2>\n<p><strong>Closing and breaking capacities:<br \/>\n<\/strong>The rated closing and breaking capacities are given in relation to the rated voltage and current used and the category of use.<\/p>\n                    <\/div>\n                                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"expertise-section expertise-section--image expertise-section--dark\">\n\n    \n        <div class=\"container\">\n                        \n            \n                \n                                    <figure class=\"expertise-section__figure\">\n                        <img decoding=\"async\"\n                            src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4337.webp\"\n                            alt=\"\"\n                            loading=\"lazy\"\n                        >\n                                            <\/figure>\n                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"expertise-section expertise-section--image expertise-section--dark\">\n\n    \n        <div class=\"container\">\n                        \n            \n                \n                                    <figure class=\"expertise-section__figure\">\n                        <img decoding=\"async\"\n                            src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4338.webp\"\n                            alt=\"\"\n                            loading=\"lazy\"\n                        >\n                                            <\/figure>\n                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"expertise-section expertise-section--image expertise-section--dark\">\n\n    \n        <div class=\"container\">\n                        \n            \n                \n                                    <figure class=\"expertise-section__figure\">\n                        <img decoding=\"async\"\n                            src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4339.webp\"\n                            alt=\"\"\n                            loading=\"lazy\"\n                        >\n                                            <\/figure>\n                \n                    <\/div>\n\n    <\/section>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\">Requirements of IEC 60309-1 and IEC 60947-3 vs MARECHAL<sup>\u00ae<\/sup> performance:<\/h2>\n\n\n<section class=\"expertise-section expertise-section--image expertise-section--dark expertise-section--image-p65\">\n\n    \n        <div class=\"container\">\n                        \n            \n                \n                                    <figure class=\"expertise-section__figure\">\n                        <img decoding=\"async\"\n                            src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/08\/Groupe-4340.webp\"\n                            alt=\"\"\n                            loading=\"lazy\"\n                        >\n                                            <\/figure>\n                \n                    <\/div>\n\n    <\/section>\n\n\n<section class=\"cta-final cta-final--dark cta-final--has-video\">\n            <video\n            class=\"cta-final__video\"\n            autoplay muted loop playsinline preload=\"none\"\n            data-lazy-video=\"viewport\"\n            data-src=\"https:\/\/marechal.com\/wp-content\/uploads\/2026\/07\/marechal-homepage-contact-background.mp4\"\n        ><\/video>\n    \n    <div class=\"cta-final__container\">\n        <div class=\"cta-final__text\">\n                            <span class=\"cta-final__surtitle\">State-of-the-art technology<\/span>                        <h2 class=\"cta-final__title\">Choose MARECHAL ELECTRIC<\/h2>        <\/div>\n        <div class=\"cta-final__action\">\n            <a class=\"btn-arrow cta-final__btn\" href=\"\/en\/contact\">\n                <span class=\"btn-arrow__label\">CONTACT US<\/span>\n                <span class=\"btn-arrow__arrow\" aria-hidden=\"true\"><\/span>\n            <\/a>\n        <\/div>\n    <\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Breaking capacity Standard IEC\/EN 60309-1 &#8211; Plug socket-outlets for industrial use Requirements of IEC 60309-1 and IEC 60947-3 vs MARECHAL\u00ae performance:<\/p>\n","protected":false},"author":115,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/template-expertise.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-114853","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/pages\/114853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/users\/115"}],"replies":[{"embeddable":true,"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/comments?post=114853"}],"version-history":[{"count":5,"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/pages\/114853\/revisions"}],"predecessor-version":[{"id":119490,"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/pages\/114853\/revisions\/119490"}],"wp:attachment":[{"href":"https:\/\/marechal.com\/en\/wp-json\/wp\/v2\/media?parent=114853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}